ELIMINATION OF STRUCTURAL FLEXIBILITY FAILURE AND VIBRATION ANALYSIS BY APPLICATION OF PREDICTIVE MAINTENANCE METHOD OF COOLING FAN

Authors

  • ZAFER ÖMER GÜNİNDİ 05058662121
  • Ali Osman Kurban Kirsehir Ahi Evran University
  • Merdin Danışmaz Kirsehir Ahi Evran University

DOI:

https://doi.org/10.46291/ICONTECHvol6iss1pp33-41

Keywords:

Anahtar Kelimeler: Kestirimci bakım, YapısalYapısal esneklik, Titreşim analizi.

Abstract

Air fans are equipment that directs the gas phase fluid used in the industry, takes the air from one place in a certain volume and transmits it to another place. Its role in the process is to provide rapid drying of the product by the forced convection heat transfer process by creating flow in the fluid bed dryer. The air fan is a primary equipment for this process. A malfunction that may occur in this equipment causes production to stop and problems in product quality. In the measurements made with a vibration measuring device and other equipment, malfunctions that have occurred or may occur in the machine are determined as a result of the evaluation of vibration frequencies and severity. As a result, early diagnosis of damage to rotating equipment (fan, pump, compressor, etc.) is one of the most important tasks of condition monitoring-oriented maintenance programs. In each rotating equipment, many different faults (bearing and gear failure, unbalance, etc.) may occur. Structural flexibility is one of these failures, which is also seen as a machine failure. However, structural flexibility failure is very difficult to detect with sensor vibration trend monitoring methods fixed on the equipment from a single point. In order to detect the structural flexibility failure by vibration analysis, the velocity spectrum, acceleration

spectrum and envelope spectrum graphs should be examined by taking measurements from all 3 axes of the bearings, and it should be ensured that they are within the permissible value ranges. Analysis with time waveform graphs does not give the expected response to structural flexibility failure. In this study, the early diagnosis of structural flexibility failure in an air fan in a mining facility is handled by spectrum analysis, by means of predictive maintenance tool vibration analyzer measurements. Spectrum analysis carried out to determine from which part and which bed region the flexibility is, is explained in detail. The fault was eliminated and the system was restored to suitable working conditions.

References

Gürsoy Demir, H. & Müştak, O. (2021). Rulman Hasarlarının Titreşim ve Gürültü Analizi ile Tespiti. Avrupa Bilim ve Teknoloji Dergisi, (25), 571-581

Gürsoy Mehmet Ümit, Çolak Umut Can, Gökçe Mahmut Hilmi, Akkulak Cem, Ötleş Semih, (2019). Endüstri İçin Kestirimci Bakım. Internatıonal Journal Of 3d Prıntıng Technologıes And Dıgıtal Industry 3:1 (2019) 56-66 Araştırma Makalesi/Research Articles

Engür Ali İhsan, Kestirimci Bakımda Titreşim Analizi, Mühendis ve Makine, Cilt : 48 Sayı: 570

Ahirrao N.S., Dr. Bhosle S.P., Dr. Nehete D.V., Dynamics and Vibration Measurements in Engines, 2nd International Conference on Metarials Manufacturing and Desing Engineering, Procedia Manufacturing 20 (2018) 434-439

Köse R. Kubilay, (2009) Topaz Makine-“Vibrasyon Analizi Eğitim Notları-1,2”

Köse R. Kubilay, Kestirimci Bakım, 1. Bakım Teknolojileri Kongresi Bildiri Kitabı, Yayın No: E/2003/334 TMMOB Makina Mühendisleri Odası 2003

Köse R. Kubilay, Kestirimci Bakım-2 2. Bakım Teknolojileri Kongresi Bildiri Kitabı, Yayın No: E/2005/370 TMMOB Makina Mühendisleri Odası 2005

Özgün Yakar, Pruftechnik Türkiye-Eğitim Notları “Titreşim Ölçüm ve Analizi Eğitimi”

Standard E. Maintenance terminology. In: European Committee for Standardization 13306, ed. Brussels, 2001.

İnce M, Bekiroğlu N, Ayçiçek E. Kestirimci Bakım Teknolojilerinin Araştırılması ve Endüstriyel Bir Motorun Amt Sistemi ile Arıza Analizlerinin Çıkarılması. Yıldız Teknik Üniversitesi Elektrik Mühendisliği Bölümü Elektrik Makinaları Anabilim Dalı, 2017.

Ayan Özcan Armağan, Döner Ekipmanların Titreşim Analizi ile Kestirimci Bakımı, Trakya Üniversitesi, Fen Bilimleri Enstitüsü, 2019.

Published

2022-03-20

How to Cite

GÜNİNDİ, Z. ÖMER, Kurban, A. O., & Danışmaz, M. (2022). ELIMINATION OF STRUCTURAL FLEXIBILITY FAILURE AND VIBRATION ANALYSIS BY APPLICATION OF PREDICTIVE MAINTENANCE METHOD OF COOLING FAN. ICONTECH INTERNATIONAL JOURNAL, 6(1), 33–41. https://doi.org/10.46291/ICONTECHvol6iss1pp33-41